Bitumen and bituminous binders - Determination of dynamic viscosity by vacuum capillary
This European Standard specifies a method for the determination of the dynamic viscosity of bituminous
binders by means of a vacuum capillary viscometer at 60 °C in a range between 0,003 6 Pa⋅s and
580 000 Pa⋅s. Other temperatures are possible if calibration constants are known. Bituminous emulsions are
not within the scope of this method.
NOTE 1 Emulsions containing bituminous binders are not considered to be covered by this method. This method can
be used for recovered and/or stabilized binders obtained from emulsions.
NOTE 2 The viscosity behaviour of some polymer modified bitumens (PMB) is not demonstrated in a vacuum capillary
viscometer. Other methods are more relevant.
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ:
CYS EN 12596:2014
This European Standard specifies a method for the determination of the dynamic viscosity of bituminous
binders by means of a vacuum capillary viscometer at 60 °C in a range between 0,003 6 Pa⋅s and
580 000 Pa⋅s. Other temperatures are possible if calibration constants are known. Bituminous emulsions are
not within the scope of this method.
NOTE 1 Emulsions containing bituminous binders are not considered to be covered by this method. This method can
be used for recovered and/or stabilized binders obtained from emulsions.
NOTE 2 The viscosity behaviour of some polymer modified bitumens (PMB) is not demonstrated in a vacuum capillary
viscometer. Other methods are more relevant.