High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation
structural requirements and test methods of high voltage/low voltage or low voltage/high
voltage prefabricated substations, which are cable-connected, to be operated from inside
(walk-in type) or outside (non-walk-in type) for alternating current of rated voltages above
1 kV and up to and including 52 kV on the high voltage side, and for one or more transformers
for service frequencies up to and including 60 Hz for outdoor installation at locations with
public accessibility and where protection of personnel is provided.
Prefabricated substations can be situated at ground level or partially or completely below
ground level.
In general a prefabricated substation comprises an enclosure containing the following
electrical components:
– power transformers;
– high voltage and low voltage switchgear and controlgear;
– high voltage and low voltage interconnections;
– auxiliary equipment and circuits.
However, relevant provisions of this standard are applicable to designs where not all these
electrical components exist (for example, an installation consisting of power transformer and
low voltage switchgear).
Non-prefabricated substations should comply with the applicable requirements of IEC 61936-
1:2010.
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ:
CYS EN 62271-202:2014
structural requirements and test methods of high voltage/low voltage or low voltage/high
voltage prefabricated substations, which are cable-connected, to be operated from inside
(walk-in type) or outside (non-walk-in type) for alternating current of rated voltages above
1 kV and up to and including 52 kV on the high voltage side, and for one or more transformers
for service frequencies up to and including 60 Hz for outdoor installation at locations with
public accessibility and where protection of personnel is provided.
Prefabricated substations can be situated at ground level or partially or completely below
ground level.
In general a prefabricated substation comprises an enclosure containing the following
electrical components:
– power transformers;
– high voltage and low voltage switchgear and controlgear;
– high voltage and low voltage interconnections;
– auxiliary equipment and circuits.
However, relevant provisions of this standard are applicable to designs where not all these
electrical components exist (for example, an installation consisting of power transformer and
low voltage switchgear).
Non-prefabricated substations should comply with the applicable requirements of IEC 61936-
1:2010.