Measuring relays and protection equipment - Part 187-1: Functional requirements for differential protection - Restrained and unrestrained differential protection of motors, generators and transformers (IEC 60255-187-1:2021)
This part of IEC 60255 specifies the minimum requirements for functional and performance
evaluation of (longitudinal) differential protection designed for the detection of faults in ac
motors, generators and transformers. This document also defines how to document and publish
performance test results.
This document covers the differential protection function whose operating characteristic can be
defined on a bias-differential plane. It includes specification of the protection function,
measurement characteristics, compensation of energizing quantities, additional restraint or
blocking methods (for overexcitation and magnetizing inrush), starting and time delay
characteristics. This document also covers unrestrained differential protection functions
traditionally combined with the restrained (biased) differential element to form a single
differential relay.
This document defines the influencing factors that affect the accuracy under steady state
conditions and performance characteristics during dynamic conditions. The test methodologies
for verifying performance characteristics and accuracy are also included in this document.
This document also includes current transformer requirements for the protection functions.
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ:
CYS EN IEC 60255-187-1:2021
This part of IEC 60255 specifies the minimum requirements for functional and performance
evaluation of (longitudinal) differential protection designed for the detection of faults in ac
motors, generators and transformers. This document also defines how to document and publish
performance test results.
This document covers the differential protection function whose operating characteristic can be
defined on a bias-differential plane. It includes specification of the protection function,
measurement characteristics, compensation of energizing quantities, additional restraint or
blocking methods (for overexcitation and magnetizing inrush), starting and time delay
characteristics. This document also covers unrestrained differential protection functions
traditionally combined with the restrained (biased) differential element to form a single
differential relay.
This document defines the influencing factors that affect the accuracy under steady state
conditions and performance characteristics during dynamic conditions. The test methodologies
for verifying performance characteristics and accuracy are also included in this document.
This document also includes current transformer requirements for the protection functions.