Nuclear facilities - Instrumentation and control systems - Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use during normal operation and anticipated operational occurrences
IEC 61031:2020 © IEC 2020 – 9 –
NUCLEAR FACILITIES –
INSTRUMENTATION AND CONTROL SYSTEMS –
DESIGN, LOCATION AND APPLICATION CRITERIA FOR
INSTALLED AREA GAMMA RADIATION DOSE RATE MONITORING
EQUIPMENT FOR USE DURING NORMAL OPERATION AND ANTICIPATED
OPERATIONAL OCCURRENCES
1 Scope
This document applies to the design, location and application of installed equipment for
monitoring local gamma radiation dose rates within nuclear facilities during normal operation
and anticipated operational occurrences. High range area gamma radiation dose rate
monitoring equipment for accident conditions currently addressed by IEC 60951-1 and
IEC 60951-3 is not within the scope of this document.
This document does not apply to the measurement of neutron dose rate. Additional equipment
for neutron monitoring may be required, depending on the plant design, if the neutron dose
rate makes a substantial contribution to the total dose equivalent to personnel.
This document provides guidelines for the design principles, the location, the application,
the calibration, the operation, and the testing of installed equipment for continuously
monitoring local gamma radiation dose rates in nuclear facilities under normal operation
conditions and anticipated operational occurrences. These instruments are normally referred
to as area radiation monitors. Portable instruments are also used for this purpose but are not
covered by this document.
Radiation monitors utilized in area radiation monitoring equipment are ad dr es s ed in
IEC 60532. As discussed in IEC 60532, measurement of gamma radiation may be expressed
by a number of alternative quantities depending on national regulations. However, for this
type of instrument, the most likely quantity to be measured is the air kerma (Gy), or the
ambient dose equivalent H*(10)(Sv).
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ:
CYS EN IEC 61031:2022
IEC 61031:2020 © IEC 2020 – 9 –
NUCLEAR FACILITIES –
INSTRUMENTATION AND CONTROL SYSTEMS –
DESIGN, LOCATION AND APPLICATION CRITERIA FOR
INSTALLED AREA GAMMA RADIATION DOSE RATE MONITORING
EQUIPMENT FOR USE DURING NORMAL OPERATION AND ANTICIPATED
OPERATIONAL OCCURRENCES
1 Scope
This document applies to the design, location and application of installed equipment for
monitoring local gamma radiation dose rates within nuclear facilities during normal operation
and anticipated operational occurrences. High range area gamma radiation dose rate
monitoring equipment for accident conditions currently addressed by IEC 60951-1 and
IEC 60951-3 is not within the scope of this document.
This document does not apply to the measurement of neutron dose rate. Additional equipment
for neutron monitoring may be required, depending on the plant design, if the neutron dose
rate makes a substantial contribution to the total dose equivalent to personnel.
This document provides guidelines for the design principles, the location, the application,
the calibration, the operation, and the testing of installed equipment for continuously
monitoring local gamma radiation dose rates in nuclear facilities under normal operation
conditions and anticipated operational occurrences. These instruments are normally referred
to as area radiation monitors. Portable instruments are also used for this purpose but are not
covered by this document.
Radiation monitors utilized in area radiation monitoring equipment are ad dr es s ed in
IEC 60532. As discussed in IEC 60532, measurement of gamma radiation may be expressed
by a number of alternative quantities depending on national regulations. However, for this
type of instrument, the most likely quantity to be measured is the air kerma (Gy), or the
ambient dose equivalent H*(10)(Sv).