Safety rules for the construction and installation of lifts - Lifts for the transport of persons and goods - Part 21: New passenger and goods passenger lifts in existing building
This document specifies the safety rules related to passenger and goods/passenger lifts installed in
existing buildings where limitations enforced by certain building constraints mean that some
requirements of EN 81-20:2020 cannot be met.
It addresses the following constraints and gives requirements for alternative solutions:
— existing perforate walls of the lift well;
— reduction in available well are leading to reduced distance between car, counterweight or balancing
weight;
— counterweight or balancing weight in a separate existing well;
— reduced building dimensions and clearances leading to:
— reductions in available space for headroom and pit;
— reduced car roof balustrade dimensions;
— reduced height of sill apron;
— reduced height of machine and/or pulley room;
— reduced available area for access door/trap door;
— reduction in available height of landing doors.
This document is not applicable to lifts installed before the date of its publication
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ:
CYS EN 81-21:2022
This document specifies the safety rules related to passenger and goods/passenger lifts installed in
existing buildings where limitations enforced by certain building constraints mean that some
requirements of EN 81-20:2020 cannot be met.
It addresses the following constraints and gives requirements for alternative solutions:
— existing perforate walls of the lift well;
— reduction in available well are leading to reduced distance between car, counterweight or balancing
weight;
— counterweight or balancing weight in a separate existing well;
— reduced building dimensions and clearances leading to:
— reductions in available space for headroom and pit;
— reduced car roof balustrade dimensions;
— reduced height of sill apron;
— reduced height of machine and/or pulley room;
— reduced available area for access door/trap door;
— reduction in available height of landing doors.
This document is not applicable to lifts installed before the date of its publication