Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts

1.1 This document specifies the additional or deviating requirements to EN 81-20:2020 for new passenger and goods passenger lifts, which can be used for firefighting and evacuation purposes under firefighters control. 1.2 This document applies, when the following conditions are fulfilled: - the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas; - the building design limits the flow of water into the lift well; - the firefighters lift is not used as an escape route; - the lift well and the lift environment are fire protected for at least to the same level as the building structure; - the power supply is secure and reliable; - the electrical cable(s) providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; - a suitable maintenance and verification plan is implemented. 1.3 This document does not cover: - the use of lifts with partially enclosed wells for use as firefighters lifts; - lifts installed in new or existing buildings, which are not included in fire resisting building structure; - important modification to existing lifts. 1.4 This document does not define: - the number of firefighters lifts and the floors to be served during firefighting operations; - size of safe area(s); - the use of other than the highest deck of a multi deck lift for firefighting operations. 1.5 This document deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer. 1.6 The following significant hazards are not dealt with in this document and are assumed to be addressed by the building designer: - not having enough or correctly located firefighters lifts to move the firefighters up the building; - a fire in the firefighters lift well, safe area, machinery space or car; - the absence of building floor identification signs at any floor; - water management is not operating correctly.
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ: CYS EN 81-72:2020
€92.00
1.1 This document specifies the additional or deviating requirements to EN 81-20:2020 for new passenger and goods passenger lifts, which can be used for firefighting and evacuation purposes under firefighters control. 1.2 This document applies, when the following conditions are fulfilled: - the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas; - the building design limits the flow of water into the lift well; - the firefighters lift is not used as an escape route; - the lift well and the lift environment are fire protected for at least to the same level as the building structure; - the power supply is secure and reliable; - the electrical cable(s) providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; - a suitable maintenance and verification plan is implemented. 1.3 This document does not cover: - the use of lifts with partially enclosed wells for use as firefighters lifts; - lifts installed in new or existing buildings, which are not included in fire resisting building structure; - important modification to existing lifts. 1.4 This document does not define: - the number of firefighters lifts and the floors to be served during firefighting operations; - size of safe area(s); - the use of other than the highest deck of a multi deck lift for firefighting operations. 1.5 This document deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer. 1.6 The following significant hazards are not dealt with in this document and are assumed to be addressed by the building designer: - not having enough or correctly located firefighters lifts to move the firefighters up the building; - a fire in the firefighters lift well, safe area, machinery space or car; - the absence of building floor identification signs at any floor; - water management is not operating correctly.
Οι πελάτες που αγόρασαν αυτό το προϊόν αγόρασαν επίσης

Safety rules for the construction and installation of lifts - Lifts for the transport of persons and goods - Part 20: Passenger and goods passenger lifts

1.1 This document specifies the safety rules for permanently installed new passenger or goods passenger lifts, with traction, positive or hydraulic drive, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by ropes or chains or jacks and moving between guide rails inclined not more than 15° to the vertical. 1.2 In addition to the requirements of this document, supplementary requirements shall be considered in special cases (use of lifts by persons with disabilities, in case of fire, potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.). 1.3 This document does not cover: a) lifts with: 1) drive systems other than those stated in 1.1; 2) rated speed ≤ 0,15 m/s; b) hydraulic lifts: 1) with a rated speed exceeding 1 m/s; 2) where the setting of the pressure relief valve exceeds 50 MPa (5.9.3.5.3); c) new passenger or goods passenger lifts in existing buildings ) where in some circumstances due to limitations enforced by building constraints, some requirements of EN 81 20 cannot be met and EN 81 21 should be considered; d) lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships' hoists, platforms for exploration or drilling at sea, construction and maintenance appliances or lifts in wind turbines; e) important modifications (see Annex C) to a lift installed before this standard is brought into application; f) safety during operations of transport, erection, repairs, and dismantling of lifts. However, this standard may usefully be taken as a basis. Noise and vibrations are not dealt with in this standard as they are not found at levels which could be considered as harmful with regard to the safe use and maintenance of the lift (see also 0.4.1). 1.4 This document is not applicable to passenger and goods passenger lifts which are installed before the date of its publication as EN. 2) Existing building is a building which is used or was already used before the order for the lift was placed. A building whose internal structure is completely renewed is considered as a new building.
€154.00

Maintenance for lifts and escalators. Rules for maintenance instructions

This European Standard specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and passenger conveyors. This European Standard does not cover: a) instructions for the installation and the dismantling; b) any legal examinations and tests based on national regulations. Existing installations are not covered by this Standard, but it can be taken as a reference.
€61.00